Thursday, 16 March 2017

SCOPE OUT YOUR SSB / AM AUDIO MODULATION !!

Use an Oscilloscope, RF Demodulator and RF Sampler to Check Exciter and Amplifier Modulation for Low Distortion and Near Perfect Amplifier and System Linearity Wipe the dust off of that old scope... Use it... You need it !!

About NU9N
First of all, let me state right up front that I am certainly no expert on measuring the complex components of a modulated RF signal. The following paragraphs are suggestions based on the information and practice that are tried and true for many.


One thing is for sure; if you take a little time to set up your scope properly, and you can achieve a decent pattern with the tests that follow, the likelihood of being overmodulated or out of linearity will greatly be reduced! Additionally, the chances of your 3rd and 5th order IMD (Inter-Modulation Distortion) products will be lower as well.

Your SSB / AM audio modulation envelope and amplifier / system linearity should be greatly improved if you can adjust your equipment to produce the classic scope patterns for the type of modulation being used. The RF Sampler and RF Demodulator circuits discussed in the writing are valuable tools when used with your oscilloscope.

May I also say that as far as I am concerned, learning how to use an oscilloscope to measure your modulation quality should be required learning for any amateur radio license, regardless of mode or frequency! An oscilloscope is an instantaneous RF measuring tool that can show details about a signal that a mere watt-meter will NEVER show. So, dust off that old scope and let's get started...

The following tests and procedures were made available courtesy of CleanRF Systems and are based on the excellent "Splatter View" combination (seen below) consisting of an RF-Demodulator and RF-Sampler that compares both pre and post linear amplifier signals as viewed on your oscilloscope. For details on the "Splatter View" visithttp://www.cleanrf.com/.



Identifying the problem:
The possibility of your 3rd and 5th order IMD (Inter-Modulation Distortion) products will be exponentially reduced; assuring that your occupied bandwidth will be directly proportional to your transmitter's audio passband, not a mistuned nonlinear amplifier.

All oscilloscopes represent a voltage displayed visually near the speed of light in real time. When used in conjunction with the model RF-D and series RF-S, great details about your signal can be acquired that a mere watt meter would never be able to display!

Note 1: Your oscilloscope's ability to measure RF will be limited by the vertical amplifier's maximum bandwidth. A 30 MHz oscilloscope or higher is therefore recommended to easily cover the entire HF radio frequency spectrum.

APPLICATION #1

Step 1 - Making the Connections:

To interface the "Splatter View" between the exciter, amplifier and antenna, use the high quality UHF male to male connectors and shielded jumper cables provided.
Connect the model RF-D (RF Demodulator) directly to the output of the transmitter, via the UHF male to male connector provided. (Choose either SO-239 connector as they are bi-directional)
Connect the series RF-S (Variable RF Sampler) directly to the output of the amplifier, via the UHF male to male connector provided. (Choose either SO-239 connector as they are bi-directional) 



Connect one of the BNC ends of your 6’ jumper cable to the BNC connector on the model RF-D (RF Demodulator) and the other end to the Horizontal (X) input of your oscilloscope.
Connect one of the BNC ends of your 6’ jumper cable to the BNC connector on the series RF-S (Variable RF Sampler) and the other end to the Vertical (Y) input of your oscilloscope.

See the wiring illustration "Figure 1" below.

Figure 1
Scope / RF Demodulator / RF Sampler Block Diagram
Note 2: The RF Demodulator's 1/4" TRS jack may be used as an AM audio modulation monitor!
Use with stereo headphones or stereo line-level unbalanced input to your mixer or stereo amplifier.
(1/4" TRS stereo plug required for line out application)

Step 2 - Initial Oscilloscope Setup:
Next, find the controls on your oscilloscope labeled "Position" for both the Horizontal and Vertical axis. Adjust the Horizontal Position control so that the horizontal sweep trace is centered horizontally. Adjust the Vertical Position control so that the horizontal sweep trace is centered vertically.
Focusing may be required. We will refer to this as establishing your "Base Line". See "Figure 2" below.
Figure 2
Establishing Initial Baseline Adjustment
Establishing Initial Baseline Adjustment
Now, set your oscilloscope's controls for the following:
  • Vertical (Y) mode selector to channel 2
  • Vertical (Y) voltage scale 2v / Div for starters
  • Both Horizontal (X) and Vertical (Y) channel coupling selectors to "DC" coupling
1 - Setting Oscilloscope for Envelope Monitoring
  • Turn off channel 1 (X) by moving coupling selector to the grounded position.
  • Turn time sweep control for 2mS / Div for starters.
  • Turn Trigger section to (X) channel.
  • An added advantage of using the trigger selection, is the ability to synchronize your horizontal modulation envelope sweep, regardless of changing voice or data modulated frequencies, in either SSB or AM envelope monitoring.
2 - Calibrating Oscilloscope and Power Output for Envelope Mode:

Tune up your exciter (transmitter) if necessary, and then your amplifier to its rated output within legal limit operation (1500w PEP). (The linearity tests discussed later in "Application 3" will determine if you tuned your amplifier properly)

With a continuous carrier established at the desired power level, adjust the "Vertical (Y) Voltage Gain" control on your oscilloscope so that the centered horizontal sweep trace expands 2 divisions above and below the baseline established in "Figure 2" on the oscilloscope's display. You should be able to make this adjustment within 10 seconds. Calibration is now complete and you can proceed to the mode you will be using (SSB or AM). See "Figure 3" below.
Figure 3
Oscilloscope Calibrated for Full Carrier Power Used
Oscilloscope Calibrated for Full Carrier Power Used

SSB Modulation Envelope Pattern:
When using the SSB or AM modes, adjust your audio gain so that your RF envelope peaks expand to the established plus and minus 2 divisions previously calibrated for, shown in "Figure 3". A well modulated SSB modulation envelope will look like "Figure 4" and an overmodulated SSB pattern is also represented in "Figure 5", both shown below.

Figure 4
Proper SSB Voice Envelope Pattern at Full Modulation / Drive Power
Proper SSB Voice Envelope Pattern at Full Modulation / Drive Power
Figure 5
Incorrect SSB Voice Envelope Pattern Showing Overmodulation / Drive Power
Incorrect SSB Voice Envelope Pattern Showing Overmodulation / Drive Power


AM Modulation Envelope Pattern:
When using AM, first calibrate an unmodulated carrier to the plus and minus 1 division level shown in "Figure 6". To achieve a fully 100% modulated envelope, adjust your audio gain so that the envelopes expand 2 divisions above and below the baseline. See "Figure 8" below. This would indicate full PEP modulation at 4 times the unmodulated carrier level. See "Figures 6, 7, 8, 9a and 9b" below.
Figure 6
AM Unmodulated Carrier Calibration
AM Unmodulated Carrier Calibration
Figure 7
Undermodulated AM Envelope
Undermodulated AM Envelope
Figure 8
100% Modulated Symetrical AM Envelope
100% Modulated Symmetrical AM Envelope
Figure 9a
Overmodulated "Low-Level" AM Envelope (Balanced Modulator)
Overmodulated "Low-Level" AM Envelope (Balanced Modulator)

Figure 9b
Overmodulated "Hghi-Level" AM Envelope (Plate Modulation)
Overmodulated "High-Level" AM Envelope (Plate Modulation)


Figure 9c
AM Asymmetry - Correct Phase
AM Asymmetry - Correct Phase (Pos 110%, Neg 95%)


Figure 9d
AM Asymmetry - Inncorect Phase
AM Asymmetry - Inncorect Phase (Pos 95%, Neg 110%) 



APPLICATION #2

Using Your Oscilloscope as an Instantaneous Peak Reading Power Meter:

Using the outlined techniques so far, you also have an excellent instantaneous peak reading power meter. If, for example, your initial adjustment on your oscilloscope was relatively based on 500 watts (measured with an existing in line meter) at the plus and minus 2 division marks on your oscilloscope, then the SSB or AM modulation envelope, as observed above, will be exactly 500 watts PEP whenever the peaks reach these divisions or any relative power level observed and set with this method.

This same method can be used with trapezoid linearity monitoring as well.
Refer to "Application 3" below.




APPLICATION #3

Trapezoidal Pattern Linearity Signal Monitor System Self Diagnostic Test:With this method, two sources will be used to feed both the Horizontal (X) and Vertical (Y) inputs of the oscilloscope, simultaneously comparing the output signal of the transmitter with the output signal of the linear amplifier.


!!!WARNING: THE MODEL RF-D (RF DEMODULATOR) MUST BE CONNECTED TO THE TRANSMITTER'S OUTPUT - NEVER TO THE AMPLIFIER'S OUTPUT. FAILURE TO COMPLY WILL DESTROY THE DEMODULATOR AND VOID YOUR WARRANTY!!!
At this time, set your oscilloscope controls as follows:

Set oscilloscope to "XY" mode. (No horizontal sweep, small focused dot will appear - See "Note 3" below)

Most oscilloscopes will have an "XY" button. Others may provide the "XY mode" via the "A and B Sec/Div" knob. Some older oscilloscopes will not have an "XY mode" selection at all because the "X" input is the "External Horizontal Sync" input. When this is the case, simply select the "External" position on the oscilloscope's "Sweep Range" selector.

Vertical voltage scale 2v / Div for starters. - See "Note 3" below.

Both Horizontal (X) and Vertical (Y) channel coupling selectors to "DC" coupling.

Note 3: Move the focused "dot" to the far left side of the screen, then while applying voice or data modulation, adjust the voltage selection controls so that the trapezoidal pattern fills half of the screen horizontally, and plus / minus two divisions vertically.

The Horizontal (X) input of the oscilloscope will be fed by the model RF-D (RF Demodulator) via the transmitter.
The Vertical (Y) input of the oscilloscope will be fed by the series RF-S (Variable RF Sampler) via the linear amplifier.

System Self Diagnostic Test:
With your amplifier turned off or in stand by, transmit voice or data and check to see that produced is a perfect trapezoidal pattern. This is a self diagnostic test, and you must see a perfect trapezoidal pattern as you are comparing the original signal to itself. If the trapezoid looks like "Figure 10" below, then you are ready to turn your amplifier on and in the operating position to check for its linearity. If you did not produce a perfect trapezoid with the amplifier in the off or standby position, then you should contact me directly.

Adjustment of voltage scale will be required to achieve resolution - See "Note 3" above.

If your amplifier is linear, the oscilloscope pattern will look like a near perfect trapezoid (Sideways Elongated Triangle) with sharp and distinct angles during voice or data transmissions. See "Figure 10" below.
Figure 10
Linear Trapezoid Modulation Pattern
Linear Trapezoid Modulation Pattern
If your amplifier has a linearity issue, the trapezoid's widest end, opposite the point, will be flattened on the ends, or some other property of the trapezoid will be distorted with a lack of distinct angles.
See "Figures 11, 12 and 13" below.
Figure 11
Nonlinear Trapezoid Modulation Pattern
Nonlinear Trapezoid Modulation Pattern
Figure 12
Nonlinear Trapezoid Modulation Pattern
Nonlinear Trapezoid Modulation Pattern

Figure 13
Nonlinear Trapezoid Modulation Pattern
Nonlinear Trapezoid Modulation Pattern
More often than not, a nonlinear trapezoidal pattern is the result of a mistuned amplifier, particularly with the load control being set with insufficient loading. To test this, simply advance the load control slightly. With more loading of the amplifier, you will more than likely see the widest side of the trapezoid edges become nice and crisp as seen in "Figure 10" above.

If the resulting patterns displayed on the oscilloscope are well formed, your unintelligible distortion products will be significantly reduced, resulting in a one to one ratio between your audio frequency and radio frequency bandwidth. This is a step in the right direction and is more than most hams ever attempt to do in analyzing their on-air signal purity.


Conclusion
Even though these scope measuring techniques will not be as complete in determining IMD, THD and more complex forms of distortion as a true RF Spectrum analyzer, if the resulting patterns displayed on the scope are well formed, your distortion products will more than likely be well within FCC specs and guidelines for good engineering practice. It is a step in the right direction in solving common distortion problems and is more than most hams ever attempt to do in analyzing their on-air signal purity.

Have fun, and may you find "Scoping Out Your Audio" to get the full scope of things as rewarding and educational as I have...

Wednesday, 15 March 2017

List of university & Top university in Kingdom of Saudi Arabia !!

Saudi Arabia is a desert country encompassing most of the Arabian Peninsula, with Red Sea and Persian Gulf coastlines. Known as the birthplace of Islam, it’s home to the religion’s 2 most sacred mosques: Masjid al-Haram, in Mecca, destination of the annual Hajj pilgrimage, and Medina’s Masjid an-Nabawi, burial site of the prophet Muhammad. 

All programs of the engineering colleges were evaluated for "Substantial-Equivalency" recognition by the Accreditation Board for Engineering and Technology (ABET).They were found substantially equivalent to similar accredited programs in the U.S. Top 10 University List in Saudi Arabia

The Master of Business Administration offered by the University is accredited by Association to Advance Collegiate Schools of Business (AACSB)

With one of the fastest-growing higher education systems in the Middle East, Saudi Arabia offers a number of world-class institutions. Eight Saudi universities are ranked in the QS World University Rankings 2014/15, and the nation claims 12 of the top 100 universities in the Arab region, in the QS University Rankings: Arab Region 2015.As in many countries worldwide, universities in Saudi Arabia offer bachelor’s, master’s and doctoral degrees, 

Generally lasting four years, two years and three to four years respectively. While international students are generally accepted into the leading Saudi universities, restrictions amongst other lesser-known universities are likely to vary, and admission for female students is limited to a select few universities and women-only institutions.

Three Saudi universities have improved in rankings in the QS World University Rankings for the 2014-2015 academic year out of a total of 800 universities on the indexKing Fahd University of Petroleum and Minerals (KFUPM) ranked number 225, surpassing the renowned Paris Sorbonne University and the UK’s Dundee University, as well as the University of Miami and other well-known institutions.

King Saud University (KSU) also ranked 249, sharing the spot with the American University of Beirut, while King Abdulaziz University (KAU) ranked number 334, surpassing City University in London and the University of Iowa.

Top 10 University List in Saudi Arabia

Top 10 University List in Saudi Arabia

  1. King Fahd University of Petroleum and Minerals (KFUPM)
  2. King Saud University (KSU) 
  3. King Abdulaziz University (KAU)
  4. Umm Al-Qura University
  5. King Khalid University
  6. King Faisal University
  7. Al - Imam Muhammad ibn Saud Islamic University
  8. Alfaisal University
  9. Prince Sultan University
  10. Qassim University
  11. Islamic University of Medinah

List of university in Saudi Arabia

  1. King Saud University
  2. Princess Nora bint Abdul Rahman University
  3. Imam Muhammad bin Saud Islamic University
  4. Prince Sultan University
  5. Arab Open University
  6. Riyadh College of Dentistry and Pharmacy
  7. Al Yamamah University
  8. Dar Al Uloom University
  9. King Saud bin Abdulaziz University for Health Sciences
  10. Alfaisal University
  11. Arab East Colleges
  12. Almaarefa College for Science and Technology
  13. Sattam bin Abdulaziz University
  14. Al Farabi College of Dentistry and Nursing
  15. Technical Trainers College
  16. Majmaah University
  17. Shaqra University
  18. Saudi Electronic University
  19. King Abdulaziz University
  20. Umm Al-Qura University
  21. Jeddah College of Technology
  22. Effat University
  23. Dar Al-Hekma College
  24. College of Business Administration (CBA)
  25. Prince Sultan Aviation Academy
  26. Taif University
  27. Batterjee Medical College
  28. Arab Open University
  29. Prince Sultan College For Tourism and Business
  30. King Abdullah University of Science and Technology
  31. Jeddah Teacher's College
  32. College of Telecom & Electronics
  33. Jeddah Private College
  34. Jeddah College of Health Care
  35. Ibn Sina National College for Medical Studies
  36. Dammam College of Technology
  37. Dammam Community College
  38. Al Ahsa College of Technology
  39. King Fahd University for Petroleum and Minerals
  40. University of Dammam
  41. King Faisal University
  42. Prince Sultan Military College of Health Sciences
  43. Hafr Al-Batin Community College
  44. Jubail Technical College
  45. University College of Jubail
  46. Qatif College of Technology
  47. Arab Open University
  48. Prince Mohammad University
  49. Al-Kharj University
  50. Jubail Industrial College
  51. Islamic University of Medina
  52. Yanbu Industrial College
  53. Madinah College of Technology
  54. Taibah University
  55. Yanbu University College
  56. Madinah Institute for Leadership and Entrepreneurship (MILE)
  57. King Khalid University
  58. IBN Rushd College for Management Sciences
  59. College of Food and Environment Technology in Buraydah
  60. Qassim University
  61. Sulaiman Al Rajhi University
  62. Al Jawf University
  63. Jazan University
  64. University of Hail
  65. Al Baha University
  66. Najran University
  67. Northern Borders University
  68. Tabuk University
  69. Fahd bin Sultan University
  70. Institute of Public Administration

கொசு விரட்டி திரவத்தை நாம் வீட்டில் மீண்டும் உபயோகப் படுத்தலாம்!!

No automatic alt text available.வீட்டில் நாம் கொசு விரட்டி திரவத்தை கடையில் வாங்கி மின்சாரத்தில் சொருகி வைத்து கொசுக்களை விரட்டுகிறோம்.
ஒருமுறை தீர்ந்தால் அந்த பாட்டிலை தூக்கி எறியாதீர்கள்.
அந்த பாட்டிலில் சிறிதளவு ஆரத்தி எடுக்கும் கற்பூரத் துண்டுகளையும், வேப்ப எண்ணையையும் கலந்து மீண்டும் உபயோகப் படுத்தலாம்.
அதை விட கூடுதல் பயன்கள் ஏராளம். 50 மில்லி வேப்ப எண்ணை விலை சுமார் ரூ10 மட்டுமே (பதாஞ்சலியில் அல்லது நாட்டு மருந்து கடைகளில் கிடைக்கிறது).
மொத்த செலவே ரூ 11 மட்டும், ஒரு மாதத்திற்கு.
இரண்டாவது மிகப் பெரிய விஷயம், இது உடல் நலத்திற்கோ, சுவாசத்திற்கோ தீங்கு விளைவிக்காத இயற்கை எண்ணெய். கடையில் வாங்கும் கொசு விரட்டியில் அல்லோத்ரின் எனும் வேதிப் பொருள் கெடுதி விளைவிப்பதாகும்.
இதை விற்பவர்கள் இந்தியாவில் மொத்தம் நாலே நாலு உற்பத்தியாளர்கள். யோசியுங்கள், ரூ 65 பெறுமானமுள்ள இந்த வேதிப் பொருளை சுமார் 10 கோடி மக்கள் இந்தியாவில் மாதம் தோறும் வாங்குகிறார்கள். ஆக, மொத்த வியாபாரப் பரிவர்த்தனை வருடத்திற்கு ரூ 7800 கோடிகள். நான்கு கம்பெனிகளில் ஒரு கம்பெனி ஜப்பான் கூட்டுறவு. அந்நிய செலாவணியாக நம் பணம் அங்கே போகிறது.
இந்த வேதிப் பொருளை விற்று வரும் லாபப் பணத்தில் சினிமா எடுக்கிறார்கள். மக்களை மயக்க விளம்பரம் எடுத்து கோடி கோடியாக கொட்டுகிறார்கள்.
ரூ 65 விற்பனை விலையில் லாபம் 250%.
நீங்களே உங்கள் வீட்டில் செய்து கொண்டால் குறு நிறுவனங்களாகிய வேப்ப எண்ணெய் உற்பத்தி உயர்ந்து நமது விவசாயி பயனடைவான்.
இந்த விஷயத்தை நமக்குத் தெரிவித்த இந்தப் பெண்மணியைப் பாராட்டுகிறேன்.
நாம் அனைவரும் பயன் பெறவும், நாடு பயனடையவும் உங்களிடம் ஒரே ஒரு வேண்டுகோள்.
இந்த தகவலை பகிருங்கள். ஒரு பத்தாயிரம் பகிர்வுகள் நடந்தால் ஒரு நல்ல விஷயத்தை பகிர்ந்தது குறித்து ஒரு இந்தியனாகிய நான் பெருமை அடைகிறேன் ..

Friday, 10 March 2017

இனி தோல்விகளின் தமிழகமும் !!கனவிலாவது புதிய இந்தியா பிறக்குமா???

Image result for மத்திய அரசுகறுப்பு பணத்தை ஒழிக்கிறோம்... ஐம்பதே நாட்களில் ஏழை மற்றும் நடுத்தர மக்களுக்கு விடிவுகாலம் என நவம்பர் 8ம் தேதி இரவு முதல் சொல்லத்தொடங்கினார்கள். அன்று முதல் ஓலங்கல் மட்டுமே ஒலிக்கிறது. மங்கல இசைகளை காணவில்லை. அப்போதே சொன்னோம் இது நிர்வாகத்தின் கையாலகதனத்தை காட்டும் வேலை என்று... இல்லை பண மழை கொட்டும்.. கறுப்பு பணம் வரும்.. விலைவாசி குறையும் என ஆருடம் சொன்னார்கள் தொலைக்காட்சி சமூக ஆர்வல ஜோதிடர்கள்.
இப்போதும் அதன் கோர நாக்குகள் நம்மை தீண்டிக்கொண்டே இருக்கிறது... பெட்ரோல், எரிவாயு உணவுபொருட்கள் விலையேற்றம் என ? அப்படியெனில் பண மதிப்பிழப்பில் என்ன நடந்தது... ? ஒன்றுமே நடக்கவில்லை... முட்டாள்களின் செயலால் மக்கள் தங்கள் சேமிப்பை இழந்துள்ளார்கள். வங்கிகளின் வாரக்கடன் குவிந்திருக்கிறது.வங்கி வந்த பணம் எல்லாமே செல்லாது. அதை கணக்கு வைத்து திரும்ப கொடுக்க வேண்டும். கொடுக்க முடியவில்லை.
ஸ்வைப்கார்டு பயன்படுத்துங்கள் என்ற மத்தியரசின் புரோக்கர் வேலையை மக்கள் ஏற்கவில்லை. அது தன் சேமிப்பை புடுங்குமென அறிந்துவிட்டார்கள். இது மத்தியரசின் மோடியின் தோல்வி. வாராக்கடன், நிதி ஆதாரங்கள் இழப்பு என வங்கிகள் தள்ளாடுகிறது. இன்னும் சொல்லப்போனால் வங்கிகளின் பண வரவு பல்வேறு விதங்களில் முடங்கி இருக்கிறது. மிகச்சாதரணமாக உற்று நோக்கலாம்... எல்லா தொழில் துறைகளும் முடங்கியிருக்கிறது. ரியல் எஸ்டேட் முதல் விவசாயம் வரை. விளைவு வங்கிகள் மக்களிடம் புடுங்க தொடங்கிவிட்டது.
எடுத்தால் பணம், கார்டில் பொருள் வாங்கினால் பணம், இவ்வளவு இருக்க வேண்டும்.... இதற்கு மேல் இருக்க கூடாது... இவ்வளவு எடுத்தால் இவ்வளவு கட்டு... என மக்களிடமே புடுங்கி தன் ஆதாரத்தை காப்பாற்றவேண்டிய நிலைக்கு வங்கிகள் தள்ளப்பட்டுவிட்டது. ஐயாயிரம் ரூ. மினிமம் என்பது எவ்வளவு பெரிய வன்முறை தெரியுமா? ஒரு வீட்டின் வாடகை அது... நான்கு பேர் கொண்ட குடும்பத்தில் பலசரக்கு பில்தொகை அது... ஒரு கூட்டுகுடும்பத்தின் வயாதானவர்களின் மருத்துவ செலவு அது...
மல்லையாக்களிடம் ரைட் ஆஃப் செய்த வெட்ககெட்ட வங்கிகள்... மாதச்சம்பள்காரனிடம் பொருளாதாரத்தை ஆஃப் செய்கிறார்கள்... ஆள்வோர் துணையுடன்.சுவச்சா இந்தியாவில் எளியவர்களின் பணம் சுத்தமாக காலியாக்கப்படுகிறது.
வளர்ச்சி என்று வாய் நீளம் காட்டிய இந்தியனே ?    இப்ப சொல் இது உனக்கு சம்மதம் தானா ???

2012ல் சிலிண்டர் விலை₹399  ஆனால் இப்ப விலை ₹842
ஏடிஎம்-களில் 4 முறைக்கு மேல் பணம் எடுத்தால் ரூ.150 கட்டணம்
ஏடிஎம்-களில் 1 முறைக்கு மேல் Balance Enquiry செக் செய்தால் ரூ.9.20 கட்டணம்
ஏடிஎம்-களில் "CARDLESS" Deposit/Withdrawal செய்தால் ரூ.25 கட்டணம்
Nil Balance Account உள்ளவா்களுக்கு PassBook வேண்டுமென்றால் ரூ.500 கட்டணம்
இந்த நொட்டை எல்லாம் பத்தாது என்று ..இப்ப
இனி வங்கி கணக்கில் 'மினிமம் பேலன்ஸ்' ரூ.5000 இருக்கனும்
பெருநகரங்களில் இருப்பவர்கள் குறைந்தபட்ச தொகையாக ரூ.5000 மும்,
நகர்ப்புறங்களில் இருப்பவர்கள் ரூ.3000 மும்,
புறநகர் பகுதிகளில் இருப்பவர்கள் ரூ.2000 மும்,
கிராமப்புறங்களில் இருப்பவர்கள் ரூ.1000 மும் வைத்திருக்க வேண்டும்.
குறைந்த பட்ச வைப்பு தொகைக்கும் கீழ் வைத்திருப்பவர்களிடம் அபராதம் வசூலிக்கப்பட உள்ளதாகவும், இந்த முறை ஏப்ரல் 1 முதல் அமலுக்கு வர உள்ளதாகவும் *எஸ்பிஐ* அறிவித்துள்ளது.
இது என்ன வங்கியா ? அவுத்துப் போட்ட லுங்கியாடா ... கேனப்பய ஊருக்குள்ளே கிறுக்குப் பயலுக்கு நாட்டமை காெடுத்தா இப்படித்தான் இருக்கும்.... 
1.முதலில் சொன்னார்கள் வெளிநாட்டில் உள்ள கறுப்பு பணத்தை கொண்டு வந்து ஒவ்வொருவருடைய வங்கி கணக்கில் 15லட்சம் வரவு வைக்கப்படும் என்று.
2.அந்த பணத்தை போடுவதற்கு வசதியாக எல்லோருக்கும் ஒரு வங்கி கணக்கு வேண்டும் என்றார்கள்.
3.1000,500 ரூபாய்களை ஒழித்து இந்தியாவில் உள்ள கறுப்பு பணத்தை மீட்டால் புதிய இந்தியா பிறக்கும் என்றார்கள்.
கடைசியில் ஒரு இந்தியாவும் பிறக்கவில்லை என்ன செய்வது என்று யோசித்தார்கள்
உங்களிடம் ரூபாய் 5000 தா, 3000 தா என்று கேட்டால் கொடுப்பீர்களா? கொடுக்க மாட்டீர்கள்(தேச பக்தர்கள் கொடுப்பார்கள்?)
பெரு நகரங்களில் உள்ளவர்கள் 5000-மும், நகரங்களில் உள்ளவர்கள் 3000 மும், கிராமங்களில் உள்ளவர்கள் 1000-மும் நிரந்தர வைப்புத்தொகையாக வங்கி கணக்கில் வைத்தால்
இந்த பணத்தை நாம் பயன்படுத்த முடியாது.
120கோடி மக்களில் 25கோடி மக்கள் பாரத ஸ்டேட் வங்கியில் கணக்கு வைத்திருந்தால் சராசரியாக ஒரு கணக்கில் 2000-ம் என்று வைத்தாலும் 50000, 00, 00, 000 கோடி ரூபாய் மக்கள் பயன்படுத்த முடியாத பணமாக மாற்றப்படும்.
இவர் கறுப்புப் பணத்தை மீட்டு மக்களுக்கு கொடுப்பார் என்று நினைத்தால் மக்களின் சேமிப்பு பணத்தை மீட்டு கார்ப்பரேட்களுக்கு கொடுக்கப் போகிறார் ?

 மத்திய அரசின்  அட்டகாசமும், மோசம் போகும் தமிழகமும்... !
மீனவர் படுகொலையை கண்டு கொள்ளாமல் ஊர் சுற்றும் மத்திய அமைச்சர்கள் ..!!

பாகிஸ்தானை காரணம் காட்டி மேலே உள்ள காஷ்மீரை மையமாக கொண்டு அரசியல் லாபத்திற்காக நாடகமாடுகிறது மத்திய அரசு ..!!
நலத்திட்டங்கள் என்ற போர்வையில் கார்பரேட் முதலாளிகள் போடும் எலும்புத்துண்டிற்கு கீழே தமிழகத்தை மையமாக வைத்து இந்திய வளங்களை சுரண்டி போலி தேச பக்த வேஷம் போடுகிறது அதே மத்திய  அரசு..!!
தமிழனே விழித்துக்கொள் தமிழ் நாட்டை மட்டுமல்ல இந்திய நாட்டையே இந்த தீய சக்திகளிடம் இருந்து உன் வீரத்தால் காத்திடு ...!!

தொகுப்பு : மு.அஜ்மல் கான்.

Thursday, 9 March 2017

விவசாயத்தை ஒழித்து 6000 கோடியில் கிடைக்கும் மீத்தேன் வாயு !!

 Image result for சாணத்தில்
Image result for சாணத்தில்
சுத்தமான மீத்தேன் வாயு ஒரு கிலோ வேண்டுமானால் 37 கிலோ மாட்டு சாணம் தேவை. 40 கிலோ என்று கூட வைத்துகொள்ளலாம்.. 

நெடுவாசல் மீத்தேன் திட்டம் மூலம் 5 மில்லியன் டன் மீத்தேன் எடுக்க திட்டம் உள்ளது. இதற்கான பட்ஜெட் 6000 கோடி. 
கால அவகாசம் முப்பது வருடம். 

இதே அளவு மீத்தேன் வாயுவை சாணத்தில் எடுக்க வேண்டுமானால் 18 லட்சத்து 50 ஆயிரம் மாடுகள் தேவை.

இதற்கான செலவு 1850 கோடிகள்.

...........................................

இயற்கையை அழித்து பூமியை வறட்சி ஆக்கி விவசாயத்தை ஒழித்து 6000 கோடியில் கிடைக்கும் மீத்தேன் வாயுவை 1850 கோடியில் எடுக்க முடியும்.

கூடுதலாக கிடைக்கும் பலன்கள்

1) பால் வளம் பெருகும்
2) விவசாயிகள் வாழ்வு மேம்படும்
3) இயற்கை வளம் மேம்படும்.
4) விவசாயம் செழிக்கும்.
5) முக்கியமாக சுற்றுச்சூழல் பாதிக்காது.

முப்பது வருடத்தில் தீர்ந்துவிடும் மீத்தேன் தேவையில்லை.
ஆண்டாண்டுக்கும் கிடைக்கக்கூடிய சாண எரிவாயுவே நமக்குத் தேவை.

புரியாதவர்களுக்கு புரியவைப்போம்.

Ten Measurements Using an Oscilloscope Meter !!!!


Image result for Oscilloscope


1) Measuring and Viewing Voltage Waveforms


You can measure and view either DC or AC signals up to the oscilloscope’s BW using the standard voltage vs time mode of operation. Adjust the vertical setting to display the complete waveform and determine the value by counting the vertical divisions and multiplying by the vertical scale factor. Most digital storage oscilloscopeshave a measurement menu that directly displays values without forcing you to count graticules.
2) Measuring and Viewing Current Waveforms
You may view current values and waveforms using an external low-value shunt resistor. Use Ohm’s law* to determine the correct scale multiplier for the measurement. The current shunt should be connected to the “low” side of the power.
*I = E / R
3) Measuring Frequency
You can perform frequency measurements by displaying the signal waveform on the oscilloscope’s screen and adjusting the horizontal time base value until you see at least one full cycle on the display. Measure the time value for one cycle and determine the frequency using the equation Freq = 1 / time.
4) Measuring Rise Time of a Pulse
You can determine the rise time of a pulse signal in a manner similar to frequency. Adjust the horizontal time base to display the rising edge of the pulse. Rise time is defined as the time between 10% and 90% of the amplitude.
5) Measuring Capacitance
You can estimate capacitance using a simple RC circuit and noting the phase difference between applied and resultant voltage across the capacitor using both vertical channels of the oscilloscope. The phase difference is noted and the capacitance is calculated using the following formula (α is the phase angle and Z is the impedance):
Capacitance = -1 / (2 x π x frequency x Z x sin(α))
6) Measuring Amplifier Gain
You may measure the gain or amplification of a circuit using both channel one and channel two of the oscilloscope. You will monitor the input signal with one channel and the output signal with the other. The difference between the amplitudes of these two signals indicates the gain.
7) Measuring Cable Length (TDR)
You may use a simple Time Domain Reflectometer (TDR) to determine the approximate length of a cable. A single fast-rising pulse from a pulse generator is simultaneously applied to the cable and the oscilloscope’s vertical channel. The time required for the pulse to travel to the end of the cable and reflect back again is a factor of both the cable length and the cable’s dielectric constant. The formula for measuring cable length is:
Length = (velocity of propagation x time) / 2
8) Measuring Differential Signals
You can measure differential signals, such as on a twisted pair cable, by using both of the oscilloscope’s vertical channels simultaneously. Use the MATH operation CH1-CH2 if both vertical channels are set to the same scale factor.
9) Measuring Signal Spectrum (FFT)
You can use the MATH operation FFT to view a waveform in an amplitude vs frequency representation. This is a simplified spectrum analyzer-type measurement and is useful for determining the frequency components of a periodic signal.
10) Measuring Duty-Cycle of a PWM Signal
You can determine the duty cycle of a PWM signal by displaying one complete cycle on the oscilloscope’s screen, which will enable you to determine the width of the positive portion as well as the width of the negative portion. Then you calculate the duty cycle with the following formula:
Duty cycle = (pulse high / (pulse high + pulse low) x 100%